Honda EB3500X User Manual

Browse online or download User Manual for Power generators Honda EB3500X. Honda EB3500X User's Manual

  • Download
  • Add to my manuals
  • Print

Summary of Contents

Page 1 - Owner's Manual

©1985 Honda Motor Co., Ltd. — All Rights ReservedOwner's ManualEB3500X

Page 2

I’ I I 4. PRE-OPER&TUON CWECK Engine Oil CAUTION: l Engine oil is a major factor affecting engine performance and service life. Non-

Page 3

Fuel Use automotive gasoline with a pump octane number (9) of 86 or higher, or a research octane number of 91 or higher (unleaded

Page 4 - CONTENTS

Gasolines Containing Alcohol If you decide to use a gasoline containing alcohol (“gasohol”), be sure the octane rating is at least as

Page 5 - 1. WARNING LABEL LOCATION

Make sure that the AC circuit breaker is in the OFF position. The generator may be hard to start if a load is connected. AC CIR

Page 6 - EB350OX

(’ I , 5. STARTING ‘THE ENGINE 1. Turn the fuel valve to the 4N position. FUEL VALVE 2. Pull the choke rod to the CLOSE position.

Page 7 - 2. GENERATOR SAFETY

3 Make sure the auto-throttle switch is in the OFF Position, or more time ’ will be required for Warm UP. A;TO-THROTTLE SWITCH 4. Tur

Page 8

5. Pull the starter grip until compression is felt, then pull briskly. NOTE: Do not allow the starter grip to snap back. Return

Page 9 - FUEL TANK CAP

6. GENERATOR USE ra!m To prevent electrical shock from faulty appliances, the generator should be grounded. Connect a length of heavy

Page 10 - 4. PRE-OPER&TUON CWECK

AC applications : 1. Turn the voltage slector switch to either position as required. When the switch is turned to “12OV ONLY” posit

Page 11 - FUEL FILI

Oil Alert System The Oil Alert system is designed to prevent engine damage caused by an in- sufficent amount of oil in the crankca

Page 13 - AC CIRCUIT BREAKER

, i 7. STOP+lNG THE EN’GINE To stop the engine in an emergency, turn the engine switch to the OFF position. I In normal use: 1. Tur

Page 14 - 5. STARTING ‘THE ENGINE

3. Turn the fuel valve to the OFF position. FUEL VALVE 19 ;

Page 15 - ’ will be required for

8. MAINTENANCE The purpose of the maintenance schedule and adjustment is to keep the generator in the best operating condition. Inspe

Page 16 - STARTER GillP

Tool kit The tools supplied are necessary for performing some periodic maintenance, simple adjustments and repairs. Always keep the kit

Page 17 - 6. GENERATOR USE

Air cleaner service A dirty air cleaner will restrict air flow to the carburetor. To prevent car- buretor malfunction, service the

Page 18 - VOLTAGE SELECTOR

2. Wash the element in a non-flammable or high flash point solvent and dry it thoroughly. 3. Soak the element in clean engine oil

Page 19 - Oil Alert System

Sediment cup cleaning Turn the fuel valve to the OFF position. Remove the sedimerit cup and O- ring, and wash them’in nonflammable

Page 20 - 7. STOP+lNG THE EN’GINE

Spark plug service Recommended spark plug: BPR5ES (NGK) WlGEPR-U (ND) CAUTION: Never use a spark plug of incorrect heat range. To en

Page 21 - FUEL VALVE

4. Check that the spark plug washer is in good condition, and thread the spark plug in by hand to prevent cross-threading. 5. Aft

Page 22 - 8. MAINTENANCE

Spark arrester maintenance mml If the generator has been running, the muffler will be very hot. Allow it to cool before proceeding.

Page 23 - Changing oil

Thank you for purchasing a Honda generator. This manual covers operation and maintenance of the EB3500X generators. All information i

Page 24

9. TRANSPORilhWSTORAGE m When transporting ihe engine, turn the fuel valve to the OFF position and keep the engine level to prevent

Page 25 - ELEMENT

d. Drain the carburetor by loosening the drain screw. Drain the gasoline into a suitable container. 3. Change the engine oil. 4. Rem

Page 26 - Sediment cup cleaning

, ,! 10. TROUBLEtiH’OOTlklG A. When the engine will not start: 1. Is the engine switch on? 2. Does the oil alert’lamp flash when the

Page 27 - Spark plug service

6. Is gasoline reaching the carburetor? To check, place a suitable container under the drain, turn the engine switch on and loosen

Page 28

11. SPECIFICAT10NS Dimensions Model Power equipment description code EB3500X EA6 Lenght x Width x Height 605x495x485mm (23.8 x 19.5 x 19.1

Page 30 - 9. TRANSPORilhWSTORAGE

i ’ / 13. #ANGER I(IT INSUALLATION 8 x 18 mm FLANGE BOLT (41 HANGER BRACKET CAUTION: l Position the hanger at the generator’s balance poin

Page 31

14. INSTALLATION OF OPTIONAL PARTS 4 Wheel Kit Installation 1. Install the four wheels on the axle shaft. 2. Install the axle assem

Page 32 - 10. TROUBLEtiH’OOTlklG

, I 15. WARRANTY SERVICE Owner Satisfaction Your satisfaction and goodwill are important to your dealer and to us. All Honda warranty

Page 33 - DRAIN SCREW

Zone Offce Locations NORTHWEST ZONE OFFICE (includes Alaska) American Honda Motor Co., Inc. Customer Relations Department PO Box 30285 Po

Page 34 - 11. SPECIFICAT10NS

I / CONTENTS CONTENTS 1. WARNING LABEL LOCATION ... 3 2. GENERATOR SAFETY ... . ...

Page 35

, I MEMO 38

Page 36

_ .- A-‘- MEMO 39

Page 39 - Zone Offce Locations

Printed onRecycled Paper50.2002.05PRINTED IN U.S.A.31ZB460000X31-ZB4-6000POM53490Kinko’s

Page 40

1. WARNING LABEL LOCATION ATTENTION NE PAS UTILISER DANS UN ENDROIT FERME A CAUSE DU RISQUE D’EMPOISONNEMENT DU GAZ. ATENClON NO LO USE EN LUGARES

Page 41

I EB350OX HONDA MOTOR CO., LTD. MADE IN JAPAN B’ CAUTION H BE SURE TO FILL CRANKCASE WITH RECOMMENDED OIL VOLTAGE AC 12Ol24OV BEFORE USING.

Page 42

2. GENERATOR SAFETY m * To ensure safe operation - Place the generator at least 1 m (3 ft) away from buildings or other equipment

Page 43 - . . ‘

.’ 3. COMPONENT IDENTIFICATION VOLTAGE SELECTOR SWITCH RECERTACLES THROTTLE SWITCH FILLER CAP OIL DRAIN PLUG VALVE RECOIL STARTER GRIP 6

Page 44

FUEL TANK CAP . 7

Comments to this Manuals

No comments