MAINTENANCE & ADJUSTMENTS
Hydrostatic Oil
Hydrostatic Oil Capacity: 10.4 quarts, 9.8 liters
Checking the Level
1.
Remove the cap on the
reservoir.
2. The oil level should be even
with the lower hole. Add oil to
bring it to the correct level.
Oil Recommendation
SAE 1 OW-40 engine oil
meeting or exceeding API
Service Classification SG.
Changing the Oil
Change the oil at the recommended interval or more
frequently under extreme operating conditions.
Drain the oil while it is warm to assure rapid and complete
draining.
1. Install one end of a section of l/z inch hose over the drain
outlet and place the other end in a suitable container to catch
the used oil.
2. Clean the area around the oil filler cap and remove it.
3. Turn the drain valve counterclockwise about 4 turns to open
it. Do not open the valve more than 6 turns to avoid
damaging the seals.
4. When the oil has drained, turn the valve clockwise to close it
and remove the section of hose. To avoid damaging the
valve, do not over tighten it.
5. Refill the reservoir with the correct amount of the
recommended oil.
6. Start the engine and allow it to idle for 3 to 5 minutes to
circulate the oil and allow any trapped air to escape.
7. Stop the engine and recheck the oil level.